Skid Structural Analysis for Heavy Equipment and Climatic Loads
See how ENA2 evaluates industrial skid structures supporting heavy equipment under seismic, wind, snow, operational, and equipment loads, including steel strength, lateral deflection, and serviceability checks.
Article Sections
Technical Overview
Structural skids are often required to support thousands of pounds of critical and high-value equipment, including pressure vessels, tanks, piping systems, pipe racks, access platforms, and other process components. In addition to these substantial equipment loads, skid structures are also expected to resist climatic loading such as wind, snow, seismic, and rain. The magnitude and distribution of these loads must therefore be carefully determined in accordance with the applicable building codes and accurately represented within the structural analysis procedure of the skid structure.
At ENA2, an advanced structural analysis software is used to develop detailed analytical models of skid structures and evaluate their response under the governing combinations of gravity, equipment, operational, and environmental loads. The structural system is then assessed in accordance with the latest applicable steel design standards to verify its structural integrity with respect to strength and serviceability. Further, the structural performance and lateral sway/drift of the skid structure is subsequently reviewed against the applicable code limits and project-specific design criteria to confirm that the skid structure meets the required levels of safety, reliability, and serviceability.
At ENA2, a wide range of engineering standards and building codes are applied, with particular emphasis on the National Building Code of Canada (NBCC) and the corresponding provincial requirements. Whether a skid structure is located in Alberta, British Columbia, Saskatchewan, Nova Scotia, Quebec, Ontario, or elsewhere in Canada, the structural design is completed in accordance with the governing building code and regulatory requirements applicable to that province. Project calculations, reports, and drawings are then stamped by a professional engineer licensed in the corresponding jurisdiction, as required.
To further strengthen the quality control process at ENA2, structural analyses, when required, can undergo independent review by a panel of experienced senior engineers. These additional reviews provide another level of technical oversight and can be professionally stamped for proper authentication. This multi-level review process at ENA2 helps ensure that the structural analysis and design is aligned with the applicable codes, standards, and professional engineering requirements.
Why Structural Analysis is Critical for Industrial Skids
Protecting expensive equipment from failure
Heavy equipment can impose high concentrated loads on skid members, potentially causing localized failures such as web crippling, flange bending, and buckling. These failures can reduce structural integrity and increase deflections, potentially damaging the supported equipment.
Assessing the member and connection behaviour
Structural analysis of skid structures allows determining the forces acting on connections. Connections subjected to seismic forces, wind uplift, and concentrated equipment loads are therefore assessed through detailed engineering calculations and FEA to verify their strength and overall conformance with engineering standards.
Determining seismic and wind demands on the structure
Seismic and wind loads acting on both the skid structure and supported equipment, determined in accordance with applicable engineering standards, are critical to evaluating multi-story skid performance. These loads govern key design checks such as lateral drift, member strength and stability, and the adequacy of the seismic force-resisting system.
Engineering decisions for safer industrial skids
Use structural analysis results to refine the design of deficient members, develop appropriate retrofit strategies, and verify compliance with applicable codes and standards. The final assessment is then documented in a stamped engineering report summarizing the analysis results, design modifications, and key engineering decisions.
Seismic and Wind Loads on Structure and Equipment
Structural Resilience Against Lateral Loads: A Fundamental Design Requirement
Seismic and wind loads are significant lateral actions that must be considered in the structural analysis and design of skid structures. Heavy equipment supported on skids can generate substantial seismic forces due to its mass, which must be properly transferred into the skid members. In addition, equipment with a large, exposed profile, such as pressure vessels, engines, and tanks, generate considerable wind loads. These equipment-induced wind forces are therefore calculated and transferred to the supporting skid structure to ensure adequate strength of the supporting skid member. Therefore, the structural analysis shall encompass:
Seismic and Wind Load Calculations for Structures – Static Procedure
The calculated base shear, represented in the formulation below and adopted from NBC 2020 seismic design provisions Section 4.1.8.11, depends on the structure ductility, weight, structural period, and site’s spectral acceleration. In addition, structure importance is another factor that further amplify seismic intensity depending on the hazard on human life in the event of failure.
Also, this formulation:
- accounts for the ductility of the structure based on the selected seismic force-resisting system
- accounts for the overstrength of the resisting system, representing its reserve strength available beyond its nominal design resistance.
The calculated wind load, determined using the formulation presented below and adopted from NBC 2020 Section 4.1.7.3, is strongly influenced by structure geometry, size and distribution of openings, exposure conditions, surrounding topography, and the site-specific velocity pressure. The formulation also accounts for internal pressure effects, which may act as either positive pressure or suction depending on the skid building enclosure.
Structural skids are often installed within partially or fully enclosed buildings; therefore, internal pressure effects can become an important component of the overall wind loading. Proper consideration of both external and internal pressures is essential to accurately determine the net wind forces transferred to the skid structure.
Seismic and Wind Load Calculations for Equipment – Static Procedure
The base shear on equipment and structure components is calculated in accordance with Section 4.1.8.18 NBC 2020 using the formulation below:
This formulation accounts for:
- Component ductility, Rp: represents the ability of the equipment or component to undergo inelastic deformation and dissipate seismic energy.
- Component weight, Wp: represents the seismic weight of the equipment or component.
- Height factor, Ax: accounts for the increase in seismic demand as the equipment is located at higher elevations within the supporting structure.
- Component factor, Cp: accounts for the importance of the component and the potential consequences associated with its failure, including the hazard level of the equipment contents.
- Force amplification factor, Ar: accounts for the dynamic amplification of the equipment response due to the flexibility of the equipment itself and/or the flexibility of its attachment to the supporting structure.
The wind force acting on equipment of different shapes is calculated using the formulation below in accordance with NBC Commentary I.
The wind pressure acting on equipment greatly depends on its shape profile, reflected in the Cf factor.
Structural Results Performed by ENA2 Using Dlubal RFEM: Strength and Serviceability
This four-story skid, 31 feet tall, was modeled in Dlubal RFEM 6, an advanced structural analysis and design platform well suited for complex structural systems and intricate load paths. ENAs utilizes this software for a detailed analysis of structural behavior while also verifying the adequacy and design of hot-rolled steel, cold-formed steel, timber, and concrete members and surfaces in accordance with applicable design standards.
As shown below, the complete steel framing system of the skid was modeled, together with major supported equipment such as pressure vessels, tanks, pumps, and pipe supports. These components were incorporated into the structural model so that the corresponding seismic and wind forces acting on the equipment could be accurately applied and transferred into the supporting skid members.
Some examples of load application are shown below.
Steel Strength – CSA S16 or AISC 360
ENA2 performs detailed structural analysis and design verification of all steel members to evaluate the governing failure modes, including flexure, shear, axial loading, flexural buckling, lateral-torsional buckling, and biaxial bending. In addition, the effective length of each member can be defined independently in each principal direction based on its actual support conditions, connection restraints, and field constructability, allowing the analytical model to more accurately represent the expected structural behaviour.
Structural Seismic and Wind Deflections
At ENA2, structural performance is evaluated not only in terms of strength but also through comprehensive serviceability checks. This includes assessing seismic and other lateral deflections and comparing the calculated response against the allowable limits prescribed by the NBC for Canadian projects or ASCE standards for projects in the United States.
Need Structural Analysis for an Equipment Skid?
ENA2 can evaluate equipment, operational, seismic, wind and snow loads together with member strength and serviceability requirements for industrial skid structures.